Pulse Jet Valve with parts of Solenoid Coil, Solenoid Armature, aluminum valve body, and diaphragm, is suitable for dust collector applications, in particular for reverse pulse jet filter cleaning and its variations, including bag filters, cartridge filters and envelop filters, ceramic filters and sintered metal fiber filters.
Our pulse jet valve with high performance diaphragm, and construction with material as bellow:
Nuts: Diecast aluminum
Ferrule: 305 SS
Armature: 430FR SS
Diaphragm and seals: Nitrile or Viton
Spring: 304 SS
Screws: 302 or 304 SS
All size is available, pls contact us.
Pulse Jet Valve Pulse Valve, Pulse Jet Valve, Dust Collector Valve, Pulse Solenoid Valve, Pulse Diaphragm Valve,Pulse Valve Repair Kits NINGBO BRANDO HARDWARE CO.,LTD , http://www.brandopneumatic.com
For samples with a measurement accuracy below 0.1 pH, a one-point calibration method can be used to adjust the pH meter. A pH 6.86 or pH 7.00 standard buffer is generally used. Some acidometers have an accuracy of only 0.2 or 0.1 pH, and only one "positioning" adjustment knob is provided on the pH meter.
The procedure for operating a one-point calibration is as follows:
(1) First measure the standard buffer temperature, look up the table to determine the value of the pHs, and adjust the temperature compensation knob to this temperature.
(2) Rinse the electrode with pure water and spin dry.
(3) After immersing the electrode in the buffer solution, shake it and place it still. After the reading is stable, adjust the positioning knob to make the instrument display the pH value of the standard solution.
(4) Take out the electrode and dry it.
(5) Measure the sample temperature and adjust the pH meter temperature compensation knob to this temperature value.
(6) Immerse the electrode in the sample solution, shake it and place it still. Display a stable reading.
In addition to pulse jet valve,we also sale angle valve,valve diaphragm,Pulse Valve Repair Kits.
Be sure to know before using the pH meter>
It must be known with any pH meter that the pH meter must be calibrated with a pH standard solution before measuring the pH of the sample.