How to maintain the battery of a diesel generator?

How to maintain the battery of a diesel generator?

How to maintain the battery of a diesel generator?
Diesel Generator | Diesel Generator Price / 2017-11-14
How to maintain the battery of a diesel generator?

Starting the battery in the diesel generator set is an important part. Without starting the battery, the diesel generator cannot start normally. Therefore, it is very important to maintain the battery of the diesel generator at ordinary times. How to maintain the battery of a diesel generator?

First of all, we must pay attention to personal safety, diesel generator manufacturers introduce: maintenance of the battery should wear anti-acid apron and wear a mask or protective glasses, once the electrolyte splashed onto the skin or clothing, should immediately rinse with plenty of water.

When charging the diesel generator battery for the first time, it should be noted that the continuous charging time should not exceed 4 hours. Too long charging time will damage the service life of the battery. The ambient temperature continues to exceed 30°C (86°F) or the relative humidity continues to exceed 80% and the charging time is 8 hours.

If the battery is stored for more than 1 year, the charging time can be 12 hours.

At the end of the charging line, check that the electrolyte level is sufficient and if necessary, add the standard electrolyte with the correct specific gravity (1:1.28). Unscrew the cell grid top cover and slowly inject the electrolyte until it is located between the two scale marks in the upper part of the metal plate and as close as possible to the upper scale line. After adding it, please do not use it immediately. You should leave the battery for about 15 minutes.

The battery is stored for more than 3 months and the charging time can be 8 hours.

Reminder: When charging the battery, first open the battery filter cap or vent cover, check the electrolyte level, and adjust with distilled water if necessary. In addition, in order to prevent the long-term closure of the battery grid gas can not be discharged in a timely manner and to prevent the condensation of water droplets on the top inner wall of the cell, should pay attention to the special opening of the vent to facilitate the proper circulation of air.

For more questions about generator sets, please call the Shengfeng team. Fifteen years of professional experience in the production and sales of power generation equipment, more professional team of engineers to serve you, choose Shengfeng choose to rest assured, the plant covers an area of ​​10,000 square meters, with 800,000 units / year machine production capacity, welcomed the field factory.


Next post:Analysis of the reason of water intake of Cummins diesel generator set
Prev:How to identify diesel generator lubricant deterioration?