Testech Laser Particle Size Analyzer (FTech-4389)

Testech Laser Particle Size Analyzer (FTech-4389)

Model NO.: FTech-4389
Trademark: TESTECH
Transport Package: Wooden Packing
Origin: China
Model NO.: FTech-4389
Trademark: TESTECH
Transport Package: Wooden Packing
Origin: China

 
Features/Benefits:
 
l Size range: 0.1-1000µm
l Accuracy: ≤1% (GBRM D50)
l Repeatability: ≤1% (GBRM D50)
l Detector: 86 pieces (forward, lateral, backward)
l Dual lenses optical system (DLOS)
l Standard Operation Procedure (SOP)
 
 
Applications/Materials:
 
l   Chemicals, paints, inks and coatings
l   Pharmaceutical development
l   Mining and minerals, metal powders  
l   Fuel cell, electronics
l   Oil and petrochemicals, coal industry
l   Food and drink
l   Cement, ceramic, soil science,   agrochemical analysis, plastic and   polymers
 
Intelligent Particle Sizing Performance
It  has outstanding accuracy and good reliability, good repeatability, easy operating, compact body and fast test speed.
Accuracy: ≤1% (GBRM D50)
The accuracy of analyzer as verified by measurements of standard samples
a) Accuracy which approved by China National Accreditation: Satisfied.
 
Letter of Notice for Ability Verification Plan Results
Test Item Sample Lab Result
(µm)
Designated Value
(µm)
Deviation Percentage
(%)
Result
Evaluation
Mean Diameter
Dmean
2012FT-A1 13.55 14.06 -3.6 Satisfied
2012FT-A2 12.26 12.55 -2.3 Satisfied
Median Diameter
D50
2012FT-A1 13.49 14.04 -4.1 Satisfied
2012FT-A2 12.27 12.54 -2.2 Satisfied
Note: if absolute value of deviation percentage is less than or equal to 10%,it is satisfied result;if absolute value is more than 10%,it is unsatisfied result.
  1. Use standard sample to verify accuracy
Repeatability: ≤1% (GBRM D50)
The analyzer measures samples with a distribution range of 0.1-1000µm.The results under same analysis conditions yield good repeatability as shown in the following graph.
a)  Repeatability of a serial test of same sample
 
Technology for Reliable Measurement
1. Dual Lenses Optical System (DLOS) 
DLOS is a patented technology of Bettersize. It integrates forward, sideway and backward scattering to double the detection of scattering lights. Compared with single lens system, DLOS improves resolution and measuring accuracy; compared with dual beam system, DLOS provides more reliable results through a consistent wavelength and continuity of a single laser source.
2. Standard Operation Procedure (SOP)
Analysis is just one click away 
SOP of the analyzer provides an intuitive solution for standardized and automatic testing. Click once on the auto test button, the testing procedure   including water intake, bubble removal, background and obscuration measurement, testing, rinsing, saving results and printing the report will run by itself. Just add sample and the automatic analysis procedure is just one click away.
SOP not only provides a simplified procedure but also avoids human operation error; therefore, SOP ensures the repeatability and accuracy of results.
  1. Automatic Centering    
 Function
Guarantee the perfect condition of optical system:
By move the laser detector center point to the focus point of lens before each test, automatic centering function guarantees the perfect condition of optical system, therefore, provides accurate and repeatable testing results.
 
 
 
4. Accuracy Calibration:
Maintain accurate datum lifetime
This function makes operational parameters maintained at consistent conditions, producing consistent and reproducible measurement across the board for all old and new instrument alike.
 
5. Automatic Circulation and Dispersion System:
Revealing the true form of every particle through the laser
The circulation and dispersion system ensures a complete sample dispersion hence make sure that each particle would be accounted for through the laser system.
 
Specification
Testing parameter Material
Particle size distribution Suspension, emulsion, dry powder
Theory Laser diffraction
Analysis theory Mie and Fraunhofer
Testing speed 3kHz
Typical measurement time ≤10second
 Size  
Size range 0.1 - 1000µm
Number of size classes More than 100 customized grades
Accuracy ≤1% (GBRM D50)
Repeatability ≤1% (GBRM D50)
Resolution ratio Single peak, double peak, multi-peak
Optics  
Red light Max. 3mW, Semiconductor optical fiber laser, 635nm
Lens arrangement Dual lenses on the right and left of sample cell
Lens design F-Theta Lenses
Effective focal length 223mm
Detector  
Arrangement Log-spaced array
Quantity 86 pieces (forward, lateral, backward)
Light path adjustment Intelligent automatic alignment
Sample dispersion system  
Dispersion type Wet
Dispersion system Ultrasound 50W, 38 KHz .Dry burning-resistant protection system
Water circulation Centrifugal pump, 500 -2500ml/min, auto water intake and rinsing
Water capacity 600ml
Software  
21 CFR Part 11 Enable
SOP Designer Enable
Report More than 14 formats report
Auto test Enable
Data export EXCEL, PDF,WORD, JPG and etc.
System compliance  
Laser class Class I laser product
System  
Supply voltage 220VAC
Dimension 660mm x420mm x 320mm  (L x W x H)
Weight 38kg
Computer specification  
Computer interface At least a USB2.0 port required
Operation system Windows XP,  Windows 7,8 or 10
Hardware specification Intel Core I5, 4GB RAM, 250GB HDTestech Laser Particle Size Analyzer (FTech-4389)

 

 
Features/Benefits:
 
l Size range: 0.1-1000µm
l Accuracy: ≤1% (GBRM D50)
l Repeatability: ≤1% (GBRM D50)
l Detector: 86 pieces (forward, lateral, backward)
l Dual lenses optical system (DLOS)
l Standard Operation Procedure (SOP)
 
 
Applications/Materials:
 
l   Chemicals, paints, inks and coatings
l   Pharmaceutical development
l   Mining and minerals, metal powders  
l   Fuel cell, electronics
l   Oil and petrochemicals, coal industry
l   Food and drink
l   Cement, ceramic, soil science,   agrochemical analysis, plastic and   polymers
 
Intelligent Particle Sizing Performance
It  has outstanding accuracy and good reliability, good repeatability, easy operating, compact body and fast test speed.
Accuracy: ≤1% (GBRM D50)
The accuracy of analyzer as verified by measurements of standard samples
a) Accuracy which approved by China National Accreditation: Satisfied.
 
Letter of Notice for Ability Verification Plan Results
Test Item Sample Lab Result
(µm)
Designated Value
(µm)
Deviation Percentage
(%)
Result
Evaluation
Mean Diameter
Dmean
2012FT-A1 13.55 14.06 -3.6 Satisfied
2012FT-A2 12.26 12.55 -2.3 Satisfied
Median Diameter
D50
2012FT-A1 13.49 14.04 -4.1 Satisfied
2012FT-A2 12.27 12.54 -2.2 Satisfied
Note: if absolute value of deviation percentage is less than or equal to 10%,it is satisfied result;if absolute value is more than 10%,it is unsatisfied result.
  1. Use standard sample to verify accuracy
Repeatability: ≤1% (GBRM D50)
The analyzer measures samples with a distribution range of 0.1-1000µm.The results under same analysis conditions yield good repeatability as shown in the following graph.
a)  Repeatability of a serial test of same sample
 
Technology for Reliable Measurement
1. Dual Lenses Optical System (DLOS) 
DLOS is a patented technology of Bettersize. It integrates forward, sideway and backward scattering to double the detection of scattering lights. Compared with single lens system, DLOS improves resolution and measuring accuracy; compared with dual beam system, DLOS provides more reliable results through a consistent wavelength and continuity of a single laser source.
2. Standard Operation Procedure (SOP)
Analysis is just one click away 
SOP of the analyzer provides an intuitive solution for standardized and automatic testing. Click once on the auto test button, the testing procedure   including water intake, bubble removal, background and obscuration measurement, testing, rinsing, saving results and printing the report will run by itself. Just add sample and the automatic analysis procedure is just one click away.
SOP not only provides a simplified procedure but also avoids human operation error; therefore, SOP ensures the repeatability and accuracy of results.
  1. Automatic Centering    
 Function
Guarantee the perfect condition of optical system:
By move the laser detector center point to the focus point of lens before each test, automatic centering function guarantees the perfect condition of optical system, therefore, provides accurate and repeatable testing results.
 
 
 
4. Accuracy Calibration:
Maintain accurate datum lifetime
This function makes operational parameters maintained at consistent conditions, producing consistent and reproducible measurement across the board for all old and new instrument alike.
 
5. Automatic Circulation and Dispersion System:
Revealing the true form of every particle through the laser
The circulation and dispersion system ensures a complete sample dispersion hence make sure that each particle would be accounted for through the laser system.
 
Specification
Testing parameter Material
Particle size distribution Suspension, emulsion, dry powder
Theory Laser diffraction
Analysis theory Mie and Fraunhofer
Testing speed 3kHz
Typical measurement time ≤10second
 Size  
Size range 0.1 - 1000µm
Number of size classes More than 100 customized grades
Accuracy ≤1% (GBRM D50)
Repeatability ≤1% (GBRM D50)
Resolution ratio Single peak, double peak, multi-peak
Optics  
Red light Max. 3mW, Semiconductor optical fiber laser, 635nm
Lens arrangement Dual lenses on the right and left of sample cell
Lens design F-Theta Lenses
Effective focal length 223mm
Detector  
Arrangement Log-spaced array
Quantity 86 pieces (forward, lateral, backward)
Light path adjustment Intelligent automatic alignment
Sample dispersion system  
Dispersion type Wet
Dispersion system Ultrasound 50W, 38 KHz .Dry burning-resistant protection system
Water circulation Centrifugal pump, 500 -2500ml/min, auto water intake and rinsing
Water capacity 600ml
Software  
21 CFR Part 11 Enable
SOP Designer Enable
Report More than 14 formats report
Auto test Enable
Data export EXCEL, PDF,WORD, JPG and etc.
System compliance  
Laser class Class I laser product
System  
Supply voltage 220VAC
Dimension 660mm x420mm x 320mm  (L x W x H)
Weight 38kg
Computer specification  
Computer interface At least a USB2.0 port required
Operation system Windows XP,  Windows 7,8 or 10
Hardware specification Intel Core I5, 4GB RAM, 250GB HDTestech Laser Particle Size Analyzer (FTech-4389)

 