50Hz Googol Diesel Fuel Natural Gas Dual Engine for Generator 280kw-2000kw

50Hz Googol Diesel Fuel Natural Gas Dual Engine for Generator 280kw-2000kw

Model NO.: PTA, QTA Series
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: Guangdong, China
HS Code: 8502120000
Model NO.: PTA, QTA Series
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: Guangdong, China
HS Code: 8502120000
50Hz Googol Diesel Fuel Natural Gas Dual Engine For Generator 280kW-2000kW


Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.


Applied gas:

Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc

Acceptable fuel gas pressure: 5~12kPa

CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%

Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.

Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )

H2S content≤ 200mg/Nm³

NH3 content≤ 20mg/Nm³

Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M

Water content≤ 40g/Nm³ , no free water.


Acceptable working conditions:

Ambient temperature: -10° C~+40° C

(antifreeze or preheater needed for below 0° C)

Relative humidity: <90%(20° C)

Altitude: ≤ 1000m

Normal working conditions:

Genset can run at rated power on the conditions:

Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.

Standard scope of supply:
1, Gas Engine

2, AC Generator

3, Common Frame

4, Control Panel

5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug

6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor

7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic

8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body

9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor

10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve

11, Exhaust Bellows & Muffler

12, Radiator for optional

Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Googol Series Dual Fuel Generator, 1500rpm, 50Hz                      
Genset Model   HDGM388 HDGM450 HDGM500 HDGM625 HDGM750 HDGM1100 HDGM1400 HDGM1650 HDGM2250 HDGM2750
Engine Model   PTA780BG1 PTAA780BG1 PTAA890BG1 PTAA1120BG1 PTAA1340BG1 QTA2160BG1 QTA3240BG1 QTA3240BG3 QTA4320BG1 QTA5400BG1
Rating Speed  rpm 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
Frequency  Hz 50 50 50 50 50 50 50 50 50 50
Generator Continuous Output (COP) kW 240  270  300  380  450  720  900  1000  1500  1800 
Generator Prime Output (PRP) kW 280  320  360  450  550  800  1000  1200  1640  2000 
Generator Standby Output (LTP) kW 310  360  400  500  600  880  1120  1320  1800  2200 
Power Factor   0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Gas Engine Parameter                      
Engine Continuous Output  (COP) kW 272  303  341  428  515  804  964  1073  1554  1865 
Engine Prime Output  (PRP) kW 315  356  405  503  621  952  1121  1331  1865  2073 
Engine Standby Output  (LTP) kW 347  399  448  556  674  1058  1247  1457  2073  2280 
Configuration   6 In line 6 In line 8 Vee 10 Vee 12 Vee 8 Vee 12 Vee 12 Vee 16 Vee 20 Vee
Displacement  l 12.8 12.8 14.6 18.3 21.9 35.4 53.1 53.1 70.8 88.5
Bore  mm 128 128 128 128 128 170 170 170 170 170
Stroke  mm 166 166 142 142 142 195 195 195 195 195
Compression Ratio   15.5:1 15.5:1 14.6:1 14.6:1 14.6:1 13.5:1 13.5:1 13.5:1 13.5:1 13.5:1
Piston Speed  m/s 8.3 8.3 7.1 7.1 7.1 9.75 9.75 9.75 9.75 9.75
Number of Flywheel Teeth    160  160  160  160  160  218  218  218  218  218 
Flywheel House Size   SAE1-14 SAE1-14 SAE1-14 SAE1-14 SAE1-14 SAE00-18 SAE00-21 SAE00-21 SAE00-21 SAE00-21
System Parameter                      
Oil Capacity  l 40 40 32 40 45 160 180 180 240 300
Max. Allowed Oil Temperature  °C 110 110 110 110 110 110 110 110 110 110
Oil Pressure Warning  kPa 200  200  200  200  200  300  300  300  300  300 
Oil Pressure Shutdown  kPa 160  160  160  160  160  200  200  200  200  200 
Coolant Capacity for Engine  l 18 18 20 21 23 70 100 100 140 200
Max. Coolant Warning Temperature   °C 95 95 95 95 95 93 93 93 93 93
Max. Coolant Shutdown Temperature   °C 105 105 105 105 105 97 97 97 97 97
Flow of Coolant pump  m³/h 19.7 19.7 26 26 30.5 48/45 48/45 48/45 80/75 80/75
Max. Exhaust Temperature °C 520 520 480 520 525 545 520 575 530 510
Exhaust Flow m³/min 91 91 84 109 135 225 269 323 481 560
Exhaust Flange Diameter  mm 125 125 2*100 2*100 2*125 250 2*250 2*250 2*250 2*250
Charging Alternator Capacity  A 35 35 35 35 35 55 55 55 55 55
Starting Voltage  V 24 24 24 24 24 24 24 24 24 24
Fuel & Gas Consumption (PRP)                      
Fuel Consumption at 75% Load l/h 18 20 23  29  34  49  58  69  91  107 
Gas Consumption at 75% Load m³/h 31 35 35 70 86 132 155 184 246 286
Fuel Consumption at 100% Load l/h 24 31 31 39 46 66 77 92 122 143
Gas Consumption at 100% Load m³/h 41 46 75 93 115 175 206 245 328 382
Generator Parameter-MECC ALTE                      
Generator Model   ECO38-3LN/4 ECO40-1S/4 ECO40-2S/4 ECO40-1.5L/4 ECO40-VL/4 ECO43-1LN/4 ECO43-2LN/4 ECO46-1S/4 ECO46-1L/4 ECO46-2L/4
Generator Prime Output kW 280 320 360 496 576 880 1040 1200 1680 2000
Generator Efficiency @ 0.8PF   93.5% 93.5% 93.7% 94.3% 94.4% 95.8% 96.0% 96.2% 96.6% 96.8%
Genset Dimension                      
Length  mm 3100 3100 3300 3500 3600 4600 5200 5200 5600 * 5600
Width  mm 1300 1300 1500 1500 1500 2190 2190 2190 2190 * 1800
Height  mm 1700 1700 2000 2000 2000 2300 2580 2580 2800 * 2400
Genset Weight kg 2500 2500 3500 3900 4300 7650 10500 11500 13500 16500

50Hz Googol Diesel Fuel Natural Gas Dual Engine for Generator 280kw-2000kw
50Hz Googol Diesel Fuel Natural Gas Dual Engine for Generator 280kw-2000kw 50Hz Googol Diesel Fuel Natural Gas Dual Engine For Generator 280kW-2000kW


Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.


Applied gas:

Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc

Acceptable fuel gas pressure: 5~12kPa

CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%

Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.

Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )

H2S content≤ 200mg/Nm³

NH3 content≤ 20mg/Nm³

Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M

Water content≤ 40g/Nm³ , no free water.


Acceptable working conditions:

Ambient temperature: -10° C~+40° C

(antifreeze or preheater needed for below 0° C)

Relative humidity: <90%(20° C)

Altitude: ≤ 1000m

Normal working conditions:

Genset can run at rated power on the conditions:

Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.

Standard scope of supply:
1, Gas Engine

2, AC Generator

3, Common Frame

4, Control Panel

5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug

6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor

7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic

8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body

9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor

10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve

11, Exhaust Bellows & Muffler

12, Radiator for optional

Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Googol Series Dual Fuel Generator, 1500rpm, 50Hz                      
Genset Model   HDGM388 HDGM450 HDGM500 HDGM625 HDGM750 HDGM1100 HDGM1400 HDGM1650 HDGM2250 HDGM2750
Engine Model   PTA780BG1 PTAA780BG1 PTAA890BG1 PTAA1120BG1 PTAA1340BG1 QTA2160BG1 QTA3240BG1 QTA3240BG3 QTA4320BG1 QTA5400BG1
Rating Speed  rpm 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
Frequency  Hz 50 50 50 50 50 50 50 50 50 50
Generator Continuous Output (COP) kW 240  270  300  380  450  720  900  1000  1500  1800 
Generator Prime Output (PRP) kW 280  320  360  450  550  800  1000  1200  1640  2000 
Generator Standby Output (LTP) kW 310  360  400  500  600  880  1120  1320  1800  2200 
Power Factor   0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Gas Engine Parameter                      
Engine Continuous Output  (COP) kW 272  303  341  428  515  804  964  1073  1554  1865 
Engine Prime Output  (PRP) kW 315  356  405  503  621  952  1121  1331  1865  2073 
Engine Standby Output  (LTP) kW 347  399  448  556  674  1058  1247  1457  2073  2280 
Configuration   6 In line 6 In line 8 Vee 10 Vee 12 Vee 8 Vee 12 Vee 12 Vee 16 Vee 20 Vee
Displacement  l 12.8 12.8 14.6 18.3 21.9 35.4 53.1 53.1 70.8 88.5
Bore  mm 128 128 128 128 128 170 170 170 170 170
Stroke  mm 166 166 142 142 142 195 195 195 195 195
Compression Ratio   15.5:1 15.5:1 14.6:1 14.6:1 14.6:1 13.5:1 13.5:1 13.5:1 13.5:1 13.5:1
Piston Speed  m/s 8.3 8.3 7.1 7.1 7.1 9.75 9.75 9.75 9.75 9.75
Number of Flywheel Teeth    160  160  160  160  160  218  218  218  218  218 
Flywheel House Size   SAE1-14 SAE1-14 SAE1-14 SAE1-14 SAE1-14 SAE00-18 SAE00-21 SAE00-21 SAE00-21 SAE00-21
System Parameter                      
Oil Capacity  l 40 40 32 40 45 160 180 180 240 300
Max. Allowed Oil Temperature  °C 110 110 110 110 110 110 110 110 110 110
Oil Pressure Warning  kPa 200  200  200  200  200  300  300  300  300  300 
Oil Pressure Shutdown  kPa 160  160  160  160  160  200  200  200  200  200 
Coolant Capacity for Engine  l 18 18 20 21 23 70 100 100 140 200
Max. Coolant Warning Temperature   °C 95 95 95 95 95 93 93 93 93 93
Max. Coolant Shutdown Temperature   °C 105 105 105 105 105 97 97 97 97 97
Flow of Coolant pump  m³/h 19.7 19.7 26 26 30.5 48/45 48/45 48/45 80/75 80/75
Max. Exhaust Temperature °C 520 520 480 520 525 545 520 575 530 510
Exhaust Flow m³/min 91 91 84 109 135 225 269 323 481 560
Exhaust Flange Diameter  mm 125 125 2*100 2*100 2*125 250 2*250 2*250 2*250 2*250
Charging Alternator Capacity  A 35 35 35 35 35 55 55 55 55 55
Starting Voltage  V 24 24 24 24 24 24 24 24 24 24
Fuel & Gas Consumption (PRP)                      
Fuel Consumption at 75% Load l/h 18 20 23  29  34  49  58  69  91  107 
Gas Consumption at 75% Load m³/h 31 35 35 70 86 132 155 184 246 286
Fuel Consumption at 100% Load l/h 24 31 31 39 46 66 77 92 122 143
Gas Consumption at 100% Load m³/h 41 46 75 93 115 175 206 245 328 382
Generator Parameter-MECC ALTE                      
Generator Model   ECO38-3LN/4 ECO40-1S/4 ECO40-2S/4 ECO40-1.5L/4 ECO40-VL/4 ECO43-1LN/4 ECO43-2LN/4 ECO46-1S/4 ECO46-1L/4 ECO46-2L/4
Generator Prime Output kW 280 320 360 496 576 880 1040 1200 1680 2000
Generator Efficiency @ 0.8PF   93.5% 93.5% 93.7% 94.3% 94.4% 95.8% 96.0% 96.2% 96.6% 96.8%
Genset Dimension                      
Length  mm 3100 3100 3300 3500 3600 4600 5200 5200 5600 * 5600
Width  mm 1300 1300 1500 1500 1500 2190 2190 2190 2190 * 1800
Height  mm 1700 1700 2000 2000 2000 2300 2580 2580 2800 * 2400
Genset Weight kg 2500 2500 3500 3900 4300 7650 10500 11500 13500 16500

50Hz Googol Diesel Fuel Natural Gas Dual Engine for Generator 280kw-2000kw
50Hz Googol Diesel Fuel Natural Gas Dual Engine for Generator 280kw-2000kw

Hexagonal Wire Mesh

Hexagonal Wire Mesh,Galvanized Hexagonal Wire Mesh,Stainless Steel Hexagonal Wire Mesh,Hexagonal Aluminum Wire Mesh

ANPING COUNTY JINNUO HARDWARE &WIRE MESH PRODUCTCO.,LTD , https://www.jnwiremesh.com